If you are having trouble placing an order, please email us at pacnseal@charter.net
Shopping Cart
Impulse Heat Sealer Repair
Replacing the electronic timer control
Replacing the electronic timer is a simple operation that will only take a few minutes and requires a #1 & #2 Philips screwdriver to complete.


The replacement procedure below is done on a standard hand operated
impulse heat sealer and shows how simple it is to complete.



UNPLUG THE IMPULSE SEALER FROM
THE POWER OUTLET
!


First, lay the impulse heat sealer on it's side and remove the 4 screws inside
the rubber feet using a #2 Philips screwdriver. Then remove the bottom plate from the sealer.

Attached to the back of the sealers timer is a wiring harness.
Gently unplug the harness from the timer.

American International Electric impulse sealer timer control for AIE-400P

Now remove the 4 screws on the face of the timer holding it in place and remove old timer from sealer unit. This is done with a #1 Philips screwdriver.


Installation is the opposite of the removal procedure.

As you can see in the picture below, the impulse sealers timer wiring terminals are set so that the harness connector can only go on one way. Be sure to properly line up the terminals and gently re-install the plug on the back of the timer. Make certain that the plug is fully seated on the timers terminals.

American International Electric impulse heat sealer timer module showing the connector terminals. AIE-400P.

After installing the new timer in the impulse sealer and connecting the
wiring harness, reattach the bottom cover and rubber feet.

Be sure to plug the impulse sealer only into a properly grounded outlet
and test for proper operation.